Quality control, step by step

Five gates between incoming fiber and the export carton. Each one has a written limit, a record and a person responsible — and the records travel with the goods.

100% IL / RLIEC 61300-3-35AQL 0.653-year warranty
The process

Five gates, no sampling shortcuts

Assemblies are measured individually. Sampling applies to packaging and appearance, never to optical performance.

1
Incoming

Fiber, ferrules and housings checked against the lot certificate; reel labels recorded against the order.

2
Assembly

Strip, clean, epoxy and cure under controlled temperature; crimp force checked on the first piece each shift.

3
Polishing

Four-step film sequence per connector type. Every end face is inspected; ferrule geometry is measured every 200 pieces.

4
100% test

Insertion loss and return loss in both directions; end face inspected to IEC 61300-3-35.

5
Final QA

AQL 0.65 on labeling, length, packing and carton drop; test data filed by serial number.

Test limits

What we accept, what we reject

ParameterLimit
Insertion loss, single-mode patch cord≤ 0.20 dB (standard) / ≤ 0.15 dB (premium)
Return loss, UPC / APC≥ 50 dB / ≥ 60 dB
Insertion loss, MPO-12 trunk≤ 0.35 dB standard, ≤ 0.25 dB low-loss
End-faceNo scratch or pit in zone A/B, IEC 61300-3-35
Length tolerance±20 mm below 2 m, ±1% above
Final inspectionAQL 0.65, ISO 2859-1 general level II

Test data is exported as PDF by default and as CSV on request. Serial numbers on the cable label match the file, so an incoming inspection can be reconciled line by line.

Interferometer and test bench at MingFiber
Equipment

What we test with

The laboratory is inside the plant, not outsourced — results come back in minutes, not weeks.

Two interferometers

Geometry and scratch measurement, used on the sample plan and on any end face that fails the visual check.

Light source and power meter

IL measured at 850/1300 nm or 1310/1550 nm, both directions.

Climate chamber

Damp heat and thermal cycling to IEC 61753-1 on the sample plan.

OTDR

Span and breakout verification for MPO trunks and pre-terminated drop cable.

Crimp pull tester

Boot retention checked at 100 N on the first piece of every batch.

Carton drop tester

1.2 m drop test on the packed carton before the first shipment of a new artwork.

When something fails

Containment, root cause, correction

  • Contain within 4 hours — the affected serial range is quarantined in the warehouse and in transit.
  • Trace to the lot — fiber reel, ferrule batch, polishing film and operator shift.
  • Report in 24 hours — 8D format with photos, root cause and corrective action.
  • Replace or credit — free replacement on confirmed defects within the 3-year warranty.
Polishing machine
Next step

Want our QC plan for your audit?

We can send the inspection plan, the AQL table and a redacted test report before you place an order.

Chat on WhatsApp +86 159 1545 1535 · reply in ~1 h